What Is the BPC-157 & TB-500 Blend?
Co-lyophilizing BPC-157 and TB-500 simplifies laboratory protocols by eliminating the need to reconstitute and draw two separate vials. Reconstituting this blend with our peptide calculator and sterile bacteriostatic water ensures fixed proportional dosing of both compounds with every syringe draw.
BPC-157 & TB-500 Blend Dosage Chart
In a 10 mg total blend vial containing 5 mg BPC-157 and 5 mg TB-500 (1:1 ratio), adding 2.0 mL of bacteriostatic water creates a concentration of 2,500 mcg/mL per compound. A 10 unit draw on a U-100 syringe delivers 250 mcg of BPC-157 and 250 mcg of TB-500 simultaneously.
| Vial Size | Bac Water Added | Concentration | Target Research Dose | Draw Units (U-100) |
|---|---|---|---|---|
| 10 mg Total (5/5) | 2.0 mL | 2.5 mg/mL each | 250 mcg BPC / 250 mcg TB | 10.0 Units |
| 10 mg Total (5/5) | 2.0 mL | 2.5 mg/mL each | 500 mcg BPC / 500 mcg TB | 20.0 Units |
| 20 mg Total (10/10) | 4.0 mL | 2.5 mg/mL each | 250 mcg BPC / 250 mcg TB | 10.0 Units |
| 15 mg Total (10/5) | 3.0 mL | 3.33/1.67 mg/mL | 500 mcg BPC / 250 mcg TB | 15.0 Units |
How to Reconstitute the BPC-157 & TB-500 Blend
Reconstituting a multi-peptide blend vial follows standard laboratory diluent procedures, ensuring complete solubility of both active lyophilized compounds.
U-100 Syringe Graduation & Measurement Line (BPC-157 & TB-500 Blend)
5 Standard Reconstitution Steps for BPC-157 & TB-500 Blend
- Sanitize the stoppers of both the blend vial and bacteriostatic water vial with 70% isopropyl alcohol prep pads.
- Draw 2.0 mL of bacteriostatic water using a sterile mixing syringe.
- Inject water slowly down the interior glass wall of the blend vial.
- Swirl the vial gently until both compounds fully dissolve into a transparent solution.
- Store reconstituted blend in a laboratory refrigerator at 2°C–8°C.
❄️ Storage & Shelf-Life Notice (BPC-157 & TB-500 Blend)
Reconstituted BPC-157 & TB-500 Blend solution remains stable under refrigeration (2°C–8°C) for up to 28 days when prepared with Bacteriostatic Water.
⚠️ Common Preparation Mistakes to Avoid
Calculating draw units based on combined total mass (10 mg) rather than individual component concentration, shaking the vial violently, and freezing reconstituted liquid.